Integrator Resources

The official home for NAI Support

Not sure where to start? Try Quick Start Guide or ask a question below!

Toggle Components with Visual Button
JavaScript Form Processing

3U cPCI Sensor Interface Unit

INTRODUCTION

North Atlantic Industries' (NAI) Sensor Interface Unit (SIU35) is a rugged base-plate conduction-cooled that takes advantage of NAI’s rugged conduction-cooled 3U cPCI multi-function I/O boards and power supply product architecture. The SIU35 provides a high density, compact data distribution system solution for I/O intensive and/or processing applications. The SIU35 supports full I/O control and communication over Ethernet. MIL-STD-1553, ARINC 429/575, Serial or CANBus interfaces are also available as primary interfaces when the boards are configured as such. PowerPC, Intel® Core™-i7, Intel ATOM™ or ARM Single Board Computer (SBC) processors can be added for a complete processing and I/O solution. The SIU35 is designed to support up to five NAI multi-function pre-configurable I/O boards, with or without processing, that support a wide variety of interface and communications function modules, all fitted/housed in a single rugged multi-board slot SIU system chassis, which is “delivered” pre-integrated and fully tested as a system.

OBJECTIVES

This manual provides the user with basic hardware implementation and information regarding the operation and interface of the SIU35. Each SIU35 is fitted with either one to five 3U cPCI boards and a AC or DC power supply unit. Additional PSU option for “hold-up” power/time is available.

SCOPE

This manual only covers the operation of the SIU35 as a stand-alone I/O subsystem. This manual does not cover specific details relating to the operation of the specific I/O boards and function modules fitted within the SIU35. Please reference the board specific documentation for details regarding the board level configuration(s).

CONVENTIONS USED IN THIS MANUAL

SIU35 Conventions

NOTE An operating procedure, practice, or condition, etc., that is essential to emphasize.

All numbers are expressed in decimal format unless otherwise noted.

GENERAL SAFETY NOTICES

The following general safety notices supplement the specific warnings and cautions appearing elsewhere in the manual. They are recommended precautions that must be understood and applied during operation and maintenance of the instrument covered herein.

SIU35 Caution

The SIU35 is delivered as a standalone system. Besides removing the rear cover to access a board’s front panel I/O, if required, NAI recommends that the boards and power supply NOT be removed from the chassis.

REPAIR

SIU35 Caution

DO NOT ATTEMPT REPAIR. Under no circumstances should repair of this instrument be attempted. All repairs to this chassis must be accomplished at the factory.

HIGH VOLTAGE

SIU35 Danger

HIGH VOLTAGE may be used in the operation of this equipment.

INPUT POWER ALWAYS ON

SIU35 Cau Dang
Note
The design of the model SIU36 is such that input power is continuously supplied to internal circuits when connected to a main power source. To disconnect the SIU34S from external power, the external power source should first be de-energized. The power input cable can then be disconnected.

Website

SYSTEM SPECIFICATIONS AND DETAILS

Introduction

The model SIU35 is a next generation rugged systems chassis joining the NAI Sensor Interface Unit (SIU) system chassis family pedigree. The SIU35 is configured to support a wide variety of SBC and multifunction I/O boards that can be configured to support a variety of processing, communications and I/O functions that are supported under the NAI Configurable Open Systems Architecture ™ (COSA®) product families.

The SIU35 can function either as a centralized or distributed system. It can also be used to supplement existing legacy systems by easily adding sensor data acquisition as well as general I/O and communication interfaces without expensive legacy chassis and backplane redesign. It has been designed with rugged embedded industrial, military and aerospace applications in mind.

Leveraging NAI’s field-proven, unique modular architecture, the SIU35 supports standard 3U cPCI board-level compatible boards that can be fitted with a wide selection of different Intelligent I/O, motion simulation/measurement and communications functions such as:

A/D Converter

D/A Converter

I/O TTL/CMOS

RTD

I/O Discrete

I/O Differential Transceiver

Synchro/Resolver LVDT/RVDT Measurement

Synchro/Resolver LVDT/RVDT Simulation

Strain Gauge

Encoder

Dual-Channel Dual Redundant BC/RT/MT MIL-STD-1553

High-Speed Sync/Async RS232/422/423/485

ARINC 429/575

CAN bus

I/O Relay

AC Reference

Ethernet Switch

SSD/Flash

Check w/ NAI’s factory or website for latest selection of available func ons

This approach provides unprecedented flexibility for supporting existing or new applications where there are specific interfacing requirements. Significant application benefits include:

  • Independent (pre-processed) I/O functionality targeted to specific data acquisition/control areas

  • Additional capabilities, technology insertion and sensor interfacing to existing fielded applications

  • Minimal integration risk based on current field-proven, deployed technologies

Specifications

The SIU35 is designed to meet the following general product specifications and is provided as a reference. Actual configuration and usage may affect size, weight and power (SWaP) specifications. Please contact NAI for discerning/defining SWaP considerations regarding specific program configurations. See additional details herein.

General

Table 1. SIU35 General SWaP Specifications

Input Voltage:

Standard/Default: DC: 18 to 36 VDC (28 VDC nominal)

Power (Base unit):

~10 W (PSU efficiency, at 100W load) @ 28 VDC nominal

Then, add the power calculated for the configuration specific boards module(s) power (see separate specific boards and module(s) specifications).

I/O Signal GND reference is isolated from main power source return and chassis.

Power/Heat Dissipation:

Conduction Cooled (CC):

~150 watts (maximum) when properly mounted to a cold plate, which must be maintained at a temperature not to exceed 71°C.

NOTE: The total SIU35 power dissipation is dependent on the configuration of the boards and function module types fixed in the SIU35. Environmental and other operating characteristic variable considerations should be considered.

Temperature, Operating:

-40°C to 71°C

Conduction cooled: As measured at primary thermal transfer interface.

Temperature, Storage:

-55°C to 105°C

Size:

Height: ~4.8” (122 mm)

Depth: ~8.7” (221 mm)

Width: ~7.1” (180 mm)

Weight:

The weight of an SIU35 system is dependent on the configuration. The approximate weight of the SIU35 is based on the selection of the PSU, boards and functional module(s).

The approximate weight of a configured SIU35 is:

~9.2 lbs. unpopulated1 - Chassis/backplane/rigid flex & connector boards/PSU (conduction cooled)

(1 includes ~2.2 lbs. for PSU)

~16.0 lbs. fully populated2

(2 includes ~1.35 lbs. for each additional fully function module populated board)

UNPACKING AND INSPECTION

Unpacking

The SIU35 packing materials were designed specifically for transport protection of the SIU35. When receiving the shipment container, inspect packaging for any evidence of physical damage. If damage is evident, it is recommended that the carrier agent is present when opening the shipping container. It is further recommended that all packing material is retained in the event the SIU35 needs to be shipped elsewhere.

System/Chassis Identification

An identification label, indicating part number, unique serial number and Ethernet PHY MACs / default IP address(es) is affixed to the system chassis.

SIU35 Labelling

Label information provided:

     Unit Level Part Number

     Unit Level Serial Number

     Unit Level Date Code

Also, typically provided with:

     Slot/Board configuration(s) as applicable

     Slot/Board serial numbers and D/C

     Slot/Board IP address / MAC address (if applicable)

Special labeling requirements are also considered (i.e. UID matrix, customer part number, etc.). Contact factory for special labeling requirements.

Inspection

Inspect the chassis and connectors to ensure that they were not damaged during transit.

MECHANICAL INTERFACE

Mechanical Description

The SIU35 is a rugged, aluminum, conduction-cooled chassis that requires proper mounting to a cold-plate or surface that is maintained at 71°C or less. Three mounting holes are provided along each side of the SIU35. See the outline drawings below. Note that hardware is not supplied.

Maximum power and heat dissipation are dependent on the board and function complement chosen. Contact NAI for application guidance. See the reference outline drawing(s) below.

Mounting Requirements

The SIU35 is conduction cooled and must be mounted in accordance with the drawing. The Outline and Installation Drawing (OID) provides recommended hardware, torque, cold-plate flatness and surface finish specifications, and thermal conductivity requirements.

SIU35 Mechanical

Chassis (Earth) GND

Chassis ground point threaded insert location is on the connector face (front) of the SIU35 as shown.

SIU35 Gnd

Finish

Unless otherwise specified, the following standard finish, or equivalent per NAI process requirements applies:

  1. PRE-TREATMENT: CHEMICAL FILM COATING IAW MIL-DTL-5541, TYPE II, CLASS 3, ALL OVER.

  2. PAINT PRIMER COAT: IAW-MIL-PRF-23377, TYPE II, CLASS 2, WITH A 0.9MIL MINIMUM DRY FILM THICKNESS TO EXTERIOR SURFACES SHOWN IN PAINT MASKING FIGURES.

  3. PAINT FINISH COAT: APPLY MEDIUM TEXTURE USING PER MIL-PRF-85285, TYPE I, CLASS 2, SEMI-GLOSS BLACK WITH A DRY FILM THICKNESS OF 0.0008 TO 0.0012 TO EXTERIOR SURFACES.

  4. FINISH NOTES 2 AND 3 OMITTED FROM THERMAL INTERFACE SURFACE INDICATED & FROM ALL HARDWARE.

CONNECTOR DESIGNATIONS, LOCATIONS & DESCRIPTIONS

The Power, I/O Interface and Ethernet connectors are located on the SIU35 front panel housing.

SIU35 Connectors

REF. DES.

KEY

MANUFACTURER / MIL-DTL SPEC. (or Equiv.)

P/N

MATE P/N

J1

N

AMPHENOL

AMP 88-569779-35SN

D38999/26WJ35P

J2

A

AMPHENOL

AMP 88-569779-35SA

D38999/26WJ35PA

J3

B

AMPHENOL

AMP 88-569779-35SB

D38999/26WJ35PB

J4

C

AMPHENOL

AMP 88-569779-35SC

D38999/26WJ35PC

J7

N

MIL-DTL-D38999 Type

AMP 88-569772-35PN

D38999/26WB35SN

CONNECTOR DETAILS AND PINOUTS

Generic pinout. See module I/O section or contact factory regarding any special module I/O configuration.

J5, Primary Power Connector

Primary input power is supported on the SIU35 via the J5 connector. There are three input power options for the SIU35: 28 VDC, 115/230 1ø VAC or 270 VDC. Two unique power connectors are used; one for the 28 VDC input and one for the 115/230 1ø VAC or 270 VDC input.

28 VDC Input Connector

If 28 VDC is specified:

Part Number: TVP02RW-11-35PN, (w/ 10,000 pf conn filtering)

Equivalent to MIL-DTL-D38999 Series III and insert arrangement IAW MIL-STD-1560: Shell size 11-35 (Insert 35), “N” (Normal) key, 13 pins.

Input Mating Connector: D38999/26WB35SN or equivalent

SIU35 J5a

115/230 1ø VAC and 270 VDC Connector

If 115/230 1ø VAC and 270 VDC is specified:

Part Number: H9300W11-05PN110Y, (w/ 10,000 pf conn filtering)

Equivalent to MIL-DTL-D38999 Series III and insert arrangement IAW MIL-STD-1560: Shell size 11-5 (Insert 5), “N” (Normal) key, 5 pins.

Input Mating Connector: D38999/26W115SN or equivalent

SIU35 J5b

I/O Connectors (J1 to J4) and SLOT Designations

Connectors J1 to J4 route all the I/O from the four cPCI boards within the SIU35. The I/O pins from the cPCI (user defined and factory configured) SlotX_P2 connectors of the cPCI cards are routed through the backplane to the SIU35 front panel connectors. I/O pin-out information for the J1 to J4 is defined by the configuration of the cPCI boards and function modules fitted to the cPCI boards.

Jx Designation

SIU35 Connector MFG. P/N (or equivalent)

Board #

NAI Conn P/N

Key

J1

AMP 88-569779-35S

Slot-1

05-0270

key (N)

J2

AMP 88-569779-35SA

Slot-2/3

05-0271

key (A)

J3

AMP 88-569779-35SB

Slot-3/4

05-0272

key (B)

J4

AMP 88-569779-35SC

Slot-4/5

05-0273

key ©

SIU35 Connectors Slots

Mating Connector Information

Mating Connector Kit: NAI P/N: SIU35-CONN-KIT

Available as an optional separate line item. The mating connector kit includes 1 each (or equivalent):

J1 Mate

NAI P/N: 05-0280-COM

HD38999 Type III / D38999/26WJ35P / EN, 128-pin, N-Key

J2 Mate

NAI P/N : 05-0281-COM

HD38999 Type III / D38999/26WJ35PA / EN, 128-pin, A-Key

J3 Mate

NAI P/N : 05-0282-COM

HD38999 Type III / D38999/26WJ35PB / EN, 128-pin, B-Key

J4 Mate

NAI P/N: 05-0283-COM

HD38999 Type III / D38999/26WJ35PC / EN, 128-pin, C-Key

J5 Mate

NAI P/N : 05-0289-COM

D38999/26WB35SN / OD, 13-pin, N-Key

POWER-UP AND BASIC OPERATIONS

Panel LEDs & Functions

Front Panel Power & Status LED Indicators

SIU35 LEDs

STATUS

Indication

POWER

Indication

[extinguished]

Default

[extinguished]

OFF / Power Fault

GRN

(Status 1)

GRN

ON / Power OK

RED

(Status 2)

x

x

Status LED

  1. Single Board Computer (SBC) inserted in Slot 1, for example: 75PPC1.

    1. If the primary processor and associated peripherals are powered on and configuration status is OK, AND, the board configured I/O function module(s) are reported as configuration status “OK”, then the status LED will illuminate GRN (typically, within 10 seconds of SIU35 power-on).

    2. If the primary processor and associated peripherals are powered on and configuration status is OK, AND, the board configured I/O function module(s) are reported as configuration status NOT “OK”, then the status LED will illuminate RED (typically, within 10 seconds of SIU35 power-on).

    3. If the primary processor and associated peripherals are powered on but the configuration status is NOT “OK”, then the status LED will remain extinguished (typically, after 10 seconds of SIU35 power-on).

  2. Non-processor card inserted in Slot 1, for example: 75G5.

       NONE (STATUS LED is extinguished).

Power LED

Provided from power supply unit (PSU) or strapped accordingly - SIU35 power “ON” indication

Basic Operations

The SIU35 is delivered as a tested unit. All pins and operation have been verified. It is recommended that Power and Ethernet connections be made to verify operation of the boards fitted within the SIU35 by making use of NAI’s Embedded Soft Panel based GUI sample application that can be utilized as a board level “exercising” tool (if the SIU35 card configuration supports). The example process below describes the use of NAI’s Ethernet communications software tool.

After applying appropriate power to the SIU35, connect a host computer (laptop or similar running Windows or Linux), to the appropriate Ethernet enabled/configured board (configured/populated in slot 1) Port A or Port B. The selection of Ethernet Port A or B is dependent on Slot-1 cPCI board configuration.

Note
Ethernet port assignments, MAC address, and factory default IP address are indicated on the chassis label

For detailed supplement, please visit the NAI web-site specific product page(s).

QUALIFICATION

The SIU35 has been designed to meet the following general specifications. Cooling type, size, weight, power and environmental characteristics may affect the program requirements and the specifications as applied. Contact factory for the SIU35 Qualification Test status.

Environmental

Table 2. Environmental Qualification Testing Specifications

Environmental MIL-STD-810 (1) (unless otherwise specified)

No.

Description

Procedure

Cycles

Table

Figure

Comments

514

Random Vibe

Method 514.6, 0.1g2/Hz from 100 to 1K Hz., -3dB octave 5-100 Hz and -6dB 1K-2K Hz,(operational)

514

Sinusoidal Vibe

TBD

501

Temp (High)

3

3 periods (@ 4 hrs. ea.) within 24 hrs. cycle at 71 ºC baseplate

502

Temp (Low)

1

3 periods (@ 4 hrs. ea.) within 24 hrs. cycle at -40 ºC baseplate

503

Temp (Shock)

3

3 x 1 hr. each hot & cold cycle

507

Humidity

II

10

507.5-7

507.5-IX

Cyclic high humidity (Cycle B2)

500

Altitude (50K)

II

1

n/a

n/a

10m/s to 50,000ft for 1 hr.

513

Acceleration

II

1

513.6-II

n/a

Carrier-based Aircraft (18g’s max)

516

Shock - Operating

I

3

516.6-I

n/a

40g’s, 1 min each x 6 axis

516

Shock - Crash

V

3

516.6-I

n/a

75g’s, 1 min each x 6 axis

Ingress Protection IEC 60529 (1, 2)

No.

Description

Procedure

Cycles

Table

Figure

Comments

IP54

Dust Protection

(other - pending characterization / contact factory)

IP54

Water Splashing

(other - pending characterization / contact factory)

IP65

Dust Tight

(other - pending characterization / contact factory)

IP65

Water Jets

(other - pending characterization / contact factory)

EMI/EMC Specifications

Table 3. EMI/EMC Qualification Testing Specifications

EMC / MIL-STD-461 (1, 2) *(unless otherwise specified)

MIL-STD-461F

Method/Curve/Procedure

Comments

CE102

Conducted, Emissions, Power Leads, 10K - 10M Hz

CS101

Conducted, Susceptibility, Power Leads, 30 - 150K Hz

CS106

Conducted, Susceptibility, Power Leads

CS114

Conducted, Susceptibility, Power Leads, 10K - 10M Hz

CS115

Conducted, Susceptibility, Bulk Injection

CS116

Conducted, Susceptibility, SIN Transient 10K - 100M Hz

RE101

Radiated, Emissions, Magnetic Field, 30 - 100K Hz

RE102

Radiated, Emissions, Electric Field, 10K - 1.25G Hz

RS101

Radiated, Susceptibility, Magnetic Field, 30 - 100K Hz

RS103

Radiated, Susceptibility, Electric Field, 2M - 18G Hz

Notes:

*1 - Designed to meet / Generic Test Reports Available

*2 - Utilizing proper shielded cables and system grounding practices

HEAT DISSIPATION

The SIU35 is capable of dissipating up to a total of 125 Watts when properly mounted. Generally, the conduction cooled version thermal interface must be maintained at a temperature not to exceed 71°C. Other operating and environmental factors and variable must be considered when specifying for a higher-level system platform integration. The total SIU35 power dissipation is dependent on the configuration of the cPCI boards and power supply fitted in the SIU35.

RELIABILITY

The reliability of the SIU35 is dependent on the configuration of the OpenVPX boards and power supply fitted within it. The Mean Time between Failures is for the SIU34 configured with chassis, backplane, EMI Filter and connectors.

MTBF

The Mean Time between Failures is configuration, environment and temperature dependent. Please contact factory regarding calculations based on the specific configuration and program requirements.

SIU35 MTBF

SIGNAL PIN-OUTS

The following pinouts provides a general use guideline as an example, only. Pinout routing will be dependent on card type/configuration for optimal I/O usage. Consult NAI factory for assistance in determining specific configuration signal definitions as applicable.

Pin-Out / General / I/O Connector (Slot 1)

J1

J2

J3

J4

SIU35 Generic I/O 75G5-Z00Z00Z001WX4X

Master with 2x Gig E

J1-1

SLOT1-M1-D1

MOD1-DATIO1

J1-2

SLOT1-M1-D2

MOD1-DATIO2

J1-3

SLOT1-M1-D3

MOD1-DATIO3

J1-4

SLOT1-M1-D4

MOD1-DATIO4

J1-8

SLOT1-M1-D5

MOD1-DATIO5

J1-16

SLOT1-M1-D6

MOD1-DATIO6

J1-9

SLOT1-M1-D7

MOD1-DATIO7

J1-17

SLOT1-M1-D8

MOD1-DATIO8

J1-10

SLOT1-M1-D9

MOD1-DATIO9

J1-18

SLOT1-M1-D10

MOD1-DATIO10

J1-11

SLOT1-M1-D11

MOD1-DATIO11

J1-19

SLOT1-M1-D12

MOD1-DATIO12

J1-15

SLOT1-M1-D13

MOD1-DATIO13

J1-25

SLOT1-M1-D14

MOD1-DATIO14

J1-26

SLOT1-M1-D15

MOD1-DATIO15

J1-38

SLOT1-M1-D16

MOD1-DATIO16

J1-27

SLOT1-M1-D17

MOD1-DATIO17

J1-39

SLOT1-M1-D18

MOD1-DATIO18

J1-28

SLOT1-M1-D19

MOD1-DATIO19

J1-40

SLOT1-M1-D20

MOD1-DATIO20

J1-29

SLOT1-M1-D21

MOD1-DATIO21

J1-41

SLOT1-M1-D22

MOD1-DATIO22

J1-36

SLOT1-M1-D23

MOD1-DATIO23

J1-37

SLOT1-M1-D24

MOD1-DATIO24

J1-50

SLOT1-M1-D25

MOD1-DATIO25

J1-62

SLOT1-M1-D26

MOD1-DATIO26

J1-51

SLOT1-M1-D27

MOD1-DATIO27

J1-63

SLOT1-M1-D28

MOD1-DATIO28

J1-52

SLOT1-M1-D29

MOD1-DATIO29

J1-64

SLOT1-M1-D30

MOD1-DATIO30

J1-61

SLOT1-M1-D31

MOD1-DATIO31

J1-73

SLOT1-M1-D32

MOD1-DATIO32

J1-5

SLOT1-M2-D1

MOD2-DATIO1

J1-13

SLOT1-M2-D2

MOD2-DATIO2

J1-6

SLOT1-M2-D3

MOD2-DATIO3

J1-7

SLOT1-M2-D4

MOD2-DATIO4

J1-12

SLOT1-M2-D5

MOD2-DATIO5

J1-20

SLOT1-M2-D6

MOD2-DATIO6

J1-14

SLOT1-M2-D7

MOD2-DATIO7

J1-24

SLOT1-M2-D8

MOD2-DATIO8

J1-21

SLOT1-M2-D9

MOD2-DATIO9

J1-32

SLOT1-M2-D10

MOD2-DATIO10

J1-22

SLOT1-M2-D11

MOD2-DATIO11

J1-33

SLOT1-M2-D12

MOD2-DATIO12

J1-23

SLOT1-M2-D13

MOD2-DATIO13

J1-34

SLOT1-M2-D14

MOD2-DATIO14

J1-35

SLOT1-M2-D15

MOD2-DATIO15

J1-47

SLOT1-M2-D16

MOD2-DATIO16

J1-30

SLOT1-M2-D17

MOD2-DATIO17

J1-42

SLOT1-M2-D18

MOD2-DATIO18

J1-31

SLOT1-M2-D19

MOD2-DATIO19

J1-43

SLOT1-M2-D20

MOD2-DATIO20

J1-44

SLOT1-M2-D21

MOD2-DATIO21

J1-56

SLOT1-M2-D22

MOD2-DATIO22

J1-45

SLOT1-M2-D23

MOD2-DATIO23

J1-57

SLOT1-M2-D24

MOD2-DATIO24

J1-68

SLOT1-M3-D1

MOD3-DATIO1

J1-69

SLOT1-M3-D2

MOD3-DATIO2

J1-70

SLOT1-M3-D3

MOD3-DATIO3

J1-81

SLOT1-M3-D4

MOD3-DATIO4

J1-77

SLOT1-M3-D5

MOD3-DATIO5

J1-88

SLOT1-M3-D6

MOD3-DATIO6

J1-78

SLOT1-M3-D7

MOD3-DATIO7

J1-89

SLOT1-M3-D8

MOD3-DATIO8

J1-79

SLOT1-M3-D9

MOD3-DATIO9

J1-90

SLOT1-M3-D10

MOD3-DATIO10

J1-80

SLOT1-M3-D11

MOD3-DATIO11

J1-91

SLOT1-M3-D12

MOD3-DATIO12

J1-92

SLOT1-M3-D13

MOD3-DATIO13

J1-103

SLOT1-M3-D14

MOD3-DATIO14

J1-93

SLOT1-M3-D15

MOD3-DATIO15

J1-104

SLOT1-M3-D16

MOD3-DATIO16

J1-100

SLOT1-M3-D17

MOD3-DATIO17

J1-111

SLOT1-M3-D18

MOD3-DATIO18

J1-101

SLOT1-M3-D19

MOD3-DATIO19

J1-112

SLOT1-M3-D20

MOD3-DATIO20

J1-102

SLOT1-M3-D21

MOD3-DATIO21

J1-113

SLOT1-M3-D22

MOD3-DATIO22

J1-110

SLOT1-M3-D23

MOD3-DATIO23

J1-119

SLOT1-M3-D24

MOD3-DATIO24

J1-83

SLOT1-ETH1-R-TP0-

ETH1-TP0-

J1-82

SLOT1-ETH1-R-TP0+

ETH1-TP0+

J1-71

SLOT1-ETH1-R-TP1+

ETH1-TP1+

J1-72

SLOT1-ETH1-R-TP1-

ETH1-TP1-

J1-49

SLOT1-ETH1-R-TP2-

ETH1-TP2-

J1-48

SLOT1-ETH1-R-TP2+

ETH1-TP2+

J1-60

SLOT1-ETH1-R-TP3-

ETH1-TP3-

J1-59

SLOT1-ETH1-R-TP3+

ETH1-TP3+

J1-84

SLOT1-ETH2-R-TP0+

ETH2-TP0+

J1-85

SLOT1-ETH2-R-TP0-

ETH2-TP0-

J1-97

SLOT1-ETH2-R-TP1-

ETH2-TP1-

J1-96

SLOT1-ETH2-R-TP1+

ETH2-TP1+

J1-95

SLOT1-ETH2-R-TP2-

ETH2-TP2-

J1-94

SLOT1-ETH2-R-TP2+

ETH2-TP2+

J1-106

SLOT1-ETH2-R-TP3-

ETH2-TP3-

J1-105

SLOT1-ETH2-R-TP3+

ETH2-TP3+

J1-116

DEBUG (I2C Clock)

N/C

J1-115

DEBUG (I2C Data)

N/C

J1-117

DEBUG (cPCI-PRSTn)

N/C

J1-107

DEBUG (HDW WP)

N/C

J1-74

Serial

SER-TXD1

J1-75

Serial

SER-RXD1

J1-76

Serial

SER-GND

J1-109

DEBUG (RTC_STDBY)

N/C

Note
Typical assignments for NAI processor card for SLOT 1.

Pin-Out / General / I/O Connector (Slot 2)

J1

J2

J3

J4

SIU35 Generic I/O

75G5-Z00Z00Z000WX0X

Slave board

J2-48

SLOT2-M1-D1

MOD1-DATIO1

J2-59

SLOT2-M1-D2

MOD1-DATIO2

J2-49

SLOT2-M1-D3

MOD1-DATIO3

J2-60

SLOT2-M1-D4

MOD1-DATIO4

J2-71

SLOT2-M1-D5

MOD1-DATIO5

J2-82

SLOT2-M1-D6

MOD1-DATIO6

J2-72

SLOT2-M1-D7

MOD1-DATIO7

J2-83

SLOT2-M1-D8

MOD1-DATIO8

J2-84

SLOT2-M1-D9

MOD1-DATIO9

J2-95

SLOT2-M1-D10

MOD1-DATIO10

J2-74

SLOT2-M1-D11

MOD1-DATIO11

J2-85

SLOT2-M1-D12

MOD1-DATIO12

J2-75

SLOT2-M1-D13

MOD1-DATIO13

J2-86

SLOT2-M1-D14

MOD1-DATIO14

J2-76

SLOT2-M1-D15

MOD1-DATIO15

J2-87

SLOT2-M1-D16

MOD1-DATIO16

J2-94

SLOT2-M1-D17

MOD1-DATIO17

J2-105

SLOT2-M1-D18

MOD1-DATIO18

J2-96

SLOT2-M1-D19

MOD1-DATIO19

J2-106

SLOT2-M1-D20

MOD1-DATIO20

J2-97

SLOT2-M1-D21

MOD1-DATIO21

J2-107

SLOT2-M1-D22

MOD1-DATIO22

J2-98

SLOT2-M1-D23

MOD1-DATIO23

J2-108

SLOT2-M1-D24

MOD1-DATIO24

J2-99

SLOT2-M1-D25

MOD1-DATIO25

J2-109

SLOT2-M1-D26

MOD1-DATIO26

J2-115

SLOT2-M1-D27

MOD1-DATIO27

J2-122

SLOT2-M1-D28

MOD1-DATIO28

J2-116

SLOT2-M1-D29

MOD1-DATIO29

J2-123

SLOT2-M1-D30

MOD1-DATIO30

J2-117

SLOT2-M1-D31

MOD1-DATIO31

J2-124

SLOT2-M1-D32

MOD1-DATIO32

J2-68

SLOT2-M2-D1

MOD2-DATIO1

J2-69

SLOT2-M2-D2

MOD2-DATIO2

J2-70

SLOT2-M2-D3

MOD2-DATIO3

J2-81

SLOT2-M2-D4

MOD2-DATIO4

J2-77

SLOT2-M2-D5

MOD2-DATIO5

J2-88

SLOT2-M2-D6

MOD2-DATIO6

J2-78

SLOT2-M2-D7

MOD2-DATIO7

J2-89

SLOT2-M2-D8

MOD2-DATIO8

J2-79

SLOT2-M2-D9

MOD2-DATIO9

J2-90

SLOT2-M2-D10

MOD2-DATIO10

J2-80

SLOT2-M2-D11

MOD2-DATIO11

J2-91

SLOT2-M2-D12

MOD2-DATIO12

J2-92

SLOT2-M2-D13

MOD2-DATIO13

J2-103

SLOT2-M2-D14

MOD2-DATIO14

J2-93

SLOT2-M2-D15

MOD2-DATIO15

J2-104

SLOT2-M2-D16

MOD2-DATIO16

J2-100

SLOT2-M2-D17

MOD2-DATIO17

J2-111

SLOT2-M2-D18

MOD2-DATIO18

J2-101

SLOT2-M2-D19

MOD2-DATIO19

J2-112

SLOT2-M2-D20

MOD2-DATIO20

J2-102

SLOT2-M2-D21

MOD2-DATIO21

J2-113

SLOT2-M2-D22

MOD2-DATIO22

J2-110

SLOT2-M2-D23

MOD2-DATIO23

J2-119

SLOT2-M2-D24

MOD2-DATIO24

J2-114

SLOT2-M2-D25

MOD2-DATIO25

J2-121

SLOT2-M2-D26

MOD2-DATIO26

J2-118

SLOT2-M2-D27

MOD2-DATIO27

J2-125

SLOT2-M2-D28

MOD2-DATIO28

J2-120

SLOT2-M2-D29

MOD2-DATIO29

J2-126

SLOT2-M2-D30

MOD2-DATIO30

J2-127

SLOT2-M2-D31

MOD2-DATIO31

J2-128

SLOT2-M2-D32

MOD2-DATIO32

J2-1

SLOT2-M3-D1

MOD3-DATIO1

J2-2

SLOT2-M3-D2

MOD3-DATIO2

J2-3

SLOT2-M3-D3

MOD3-DATIO3

J2-4

SLOT2-M3-D4

MOD3-DATIO4

J2-8

SLOT2-M3-D5

MOD3-DATIO5

J2-16

SLOT2-M3-D6

MOD3-DATIO6

J2-9

SLOT2-M3-D7

MOD3-DATIO7

J2-17

SLOT2-M3-D8

MOD3-DATIO8

J2-10

SLOT2-M3-D9

MOD3-DATIO9

J2-18

SLOT2-M3-D10

MOD3-DATIO10

J2-11

SLOT2-M3-D11

MOD3-DATIO11

J2-19

SLOT2-M3-D12

MOD3-DATIO12

J2-15

SLOT2-M3-D13

MOD3-DATIO13

J2-25

SLOT2-M3-D14

MOD3-DATIO14

J2-26

SLOT2-M3-D15

MOD3-DATIO15

J2-38

SLOT2-M3-D16

MOD3-DATIO16

J2-27

SLOT2-M3-D17

MOD3-DATIO17

J2-39

SLOT2-M3-D18

MOD3-DATIO18

J2-28

SLOT2-M3-D19

MOD3-DATIO19

J2-40

SLOT2-M3-D20

MOD3-DATIO20

J2-29

SLOT2-M3-D21

MOD3-DATIO21

J2-41

SLOT2-M3-D22

MOD3-DATIO22

J2-36

SLOT2-M3-D23

MOD3-DATIO23

J2-37

SLOT2-M3-D24

MOD3-DATIO24

J2-50

SLOT2-M3-D25

MOD3-DATIO25

J2-62

SLOT2-M3-D26

MOD3-DATIO26

J2-51

SLOT2-M3-D27

MOD3-DATIO27

J2-63

SLOT2-M3-D28

MOD3-DATIO28

J2-52

SLOT2-M3-D29

MOD3-DATIO29

J2-64

SLOT2-M3-D30

MOD3-DATIO30

J2-61

SLOT2-M3-D31

MOD3-DATIO31

J2-73

SLOT2-M3-D32

MOD3-DATIO32

Pin-Out / General / I/O Connector (Slot 3)

J1

J2

J3

J4

SIU35 Generic I/O

75G5-Z00Z00Z000WX0X

Slave board

J3-48

SLOT3-M1-D1

MOD1-DATIO1

J3-59

SLOT3-M1-D2

MOD1-DATIO2

J3-49

SLOT3-M1-D3

MOD1-DATIO3

J3-60

SLOT3-M1-D4

MOD1-DATIO4

J3-71

SLOT3-M1-D5

MOD1-DATIO5

J3-82

SLOT3-M1-D6

MOD1-DATIO6

J3-72

SLOT3-M1-D7

MOD1-DATIO7

J3-83

SLOT3-M1-D8

MOD1-DATIO8

J3-84

SLOT3-M1-D9

MOD1-DATIO9

J3-95

SLOT3-M1-D10

MOD1-DATIO10

J3-74

SLOT3-M1-D11

MOD1-DATIO11

J3-85

SLOT3-M1-D12

MOD1-DATIO12

J3-75

SLOT3-M1-D13

MOD1-DATIO13

J3-86

SLOT3-M1-D14

MOD1-DATIO14

J3-76

SLOT3-M1-D15

MOD1-DATIO15

J3-87

SLOT3-M1-D16

MOD1-DATIO16

J3-94

SLOT3-M1-D17

MOD1-DATIO17

J3-105

SLOT3-M1-D18

MOD1-DATIO18

J3-96

SLOT3-M1-D19

MOD1-DATIO19

J3-106

SLOT3-M1-D20

MOD1-DATIO20

J3-97

SLOT3-M1-D21

MOD1-DATIO21

J3-107

SLOT3-M1-D22

MOD1-DATIO22

J3-98

SLOT3-M1-D23

MOD1-DATIO23

J3-108

SLOT3-M1-D24

MOD1-DATIO24

J3-99

SLOT3-M1-D25

MOD1-DATIO25

J3-109

SLOT3-M1-D26

MOD1-DATIO26

J3-115

SLOT3-M1-D27

MOD1-DATIO27

J3-122

SLOT3-M1-D28

MOD1-DATIO28

J3-116

SLOT3-M1-D29

MOD1-DATIO29

J3-123

SLOT3-M1-D30

MOD1-DATIO30

J3-117

SLOT3-M1-D31

MOD1-DATIO31

J3-124

SLOT3-M1-D32

MOD1-DATIO32

J3-68

SLOT3-M2-D1

MOD2-DATIO1

J3-69

SLOT3-M2-D2

MOD2-DATIO2

J3-70

SLOT3-M2-D3

MOD2-DATIO3

J3-81

SLOT3-M2-D4

MOD2-DATIO4

J3-77

SLOT3-M2-D5

MOD2-DATIO5

J3-88

SLOT3-M2-D6

MOD2-DATIO6

J3-78

SLOT3-M2-D7

MOD2-DATIO7

J3-89

SLOT3-M2-D8

MOD2-DATIO8

J3-79

SLOT3-M2-D9

MOD2-DATIO9

J3-90

SLOT3-M2-D10

MOD2-DATIO10

J3-80

SLOT3-M2-D11

MOD2-DATIO11

J3-91

SLOT3-M2-D12

MOD2-DATIO12

J3-92

SLOT3-M2-D13

MOD2-DATIO13

J3-103

SLOT3-M2-D14

MOD2-DATIO14

J3-93

SLOT3-M2-D15

MOD2-DATIO15

J3-104

SLOT3-M2-D16

MOD2-DATIO16

J3-100

SLOT3-M2-D17

MOD2-DATIO17

J3-111

SLOT3-M2-D18

MOD2-DATIO18

J3-101

SLOT3-M2-D19

MOD2-DATIO19

J3-112

SLOT3-M2-D20

MOD2-DATIO20

J3-102

SLOT3-M2-D21

MOD2-DATIO21

J3-113

SLOT3-M2-D22

MOD2-DATIO22

J3-110

SLOT3-M2-D23

MOD2-DATIO23

J3-119

SLOT3-M2-D24

MOD2-DATIO24

J3-114

SLOT3-M2-D25

MOD2-DATIO25

J3-121

SLOT3-M2-D26

MOD2-DATIO26

J3-118

SLOT3-M2-D27

MOD2-DATIO27

J3-125

SLOT3-M2-D28

MOD2-DATIO28

J3-120

SLOT3-M2-D29

MOD2-DATIO29

J3-126

SLOT3-M2-D30

MOD2-DATIO30

J3-127

SLOT3-M2-D31

MOD2-DATIO31

J3-128

SLOT3-M2-D32

MOD2-DATIO32

J2-5

SLOT3-M3-D1

MOD3-DATIO1

J2-13

SLOT3-M3-D2

MOD3-DATIO2

J2-6

SLOT3-M3-D3

MOD3-DATIO3

J2-7

SLOT3-M3-D4

MOD3-DATIO4

J2-12

SLOT3-M3-D5

MOD3-DATIO5

J2-20

SLOT3-M3-D6

MOD3-DATIO6

J2-14

SLOT3-M3-D7

MOD3-DATIO7

J2-24

SLOT3-M3-D8

MOD3-DATIO8

J2-21

SLOT3-M3-D9

MOD3-DATIO9

J2-32

SLOT3-M3-D10

MOD3-DATIO10

J2-22

SLOT3-M3-D11

MOD3-DATIO11

J2-33

SLOT3-M3-D12

MOD3-DATIO12

J2-23

SLOT3-M3-D13

MOD3-DATIO13

J2-34

SLOT3-M3-D14

MOD3-DATIO14

J2-35

SLOT3-M3-D15

MOD3-DATIO15

J2-47

SLOT3-M3-D16

MOD3-DATIO16

J2-30

SLOT3-M3-D17

MOD3-DATIO17

J2-42

SLOT3-M3-D18

MOD3-DATIO18

J2-31

SLOT3-M3-D19

MOD3-DATIO19

J2-43

SLOT3-M3-D20

MOD3-DATIO20

J2-44

SLOT3-M3-D21

MOD3-DATIO21

J2-56

SLOT3-M3-D22

MOD3-DATIO22

J2-45

SLOT3-M3-D23

MOD3-DATIO23

J2-57

SLOT3-M3-D24

MOD3-DATIO24

J2-46

SLOT3-M3-D25

MOD3-DATIO25

J2-58

SLOT3-M3-D26

MOD3-DATIO26

J2-53

SLOT3-M3-D27

MOD3-DATIO27

J2-65

SLOT3-M3-D28

MOD3-DATIO28

J2-54

SLOT3-M3-D29

MOD3-DATIO29

J2-66

SLOT3-M3-D30

MOD3-DATIO30

J2-55

SLOT3-M3-D31

MOD3-DATIO31

J2-67

SLOT3-M3-D32

MOD3-DATIO32

Pin-Out / General / I/O Connector (Slot 4)

J1

J2

J3

J4

SIU35 Generic I/O

75G5-Z00Z00Z000WX0X

Slave board

J3-1

SLOT4-M1-D1

MOD1-DATIO1

J3-2

SLOT4-M1-D2

MOD1-DATIO2

J3-3

SLOT4-M1-D3

MOD1-DATIO3

J3-4

SLOT4-M1-D4

MOD1-DATIO4

J3-8

SLOT4-M1-D5

MOD1-DATIO5

J3-16

SLOT4-M1-D6

MOD1-DATIO6

J3-9

SLOT4-M1-D7

MOD1-DATIO7

J3-17

SLOT4-M1-D8

MOD1-DATIO8

J3-10

SLOT4-M1-D9

MOD1-DATIO9

J3-18

SLOT4-M1-D10

MOD1-DATIO10

J3-11

SLOT4-M1-D11

MOD1-DATIO11

J3-19

SLOT4-M1-D12

MOD1-DATIO12

J3-15

SLOT4-M1-D13

MOD1-DATIO13

J3-25

SLOT4-M1-D14

MOD1-DATIO14

J3-26

SLOT4-M1-D15

MOD1-DATIO15

J3-38

SLOT4-M1-D16

MOD1-DATIO16

J3-27

SLOT4-M1-D17

MOD1-DATIO17

J3-39

SLOT4-M1-D18

MOD1-DATIO18

J3-28

SLOT4-M1-D19

MOD1-DATIO19

J3-40

SLOT4-M1-D20

MOD1-DATIO20

J3-29

SLOT4-M1-D21

MOD1-DATIO21

J3-41

SLOT4-M1-D22

MOD1-DATIO22

J3-36

SLOT4-M1-D23

MOD1-DATIO23

J3-37

SLOT4-M1-D24

MOD1-DATIO24

J3-50

SLOT4-M1-D25

MOD1-DATIO25

J3-62

SLOT4-M1-D26

MOD1-DATIO26

J3-51

SLOT4-M1-D27

MOD1-DATIO27

J3-63

SLOT4-M1-D28

MOD1-DATIO28

J3-52

SLOT4-M1-D29

MOD1-DATIO29

J3-64

SLOT4-M1-D30

MOD1-DATIO30

J3-61

SLOT4-M1-D31

MOD1-DATIO31

J3-73

SLOT4-M1-D32

MOD1-DATIO32

J3-5

SLOT4-M2-D1

MOD2-DATIO1

J3-13

SLOT4-M2-D2

MOD2-DATIO2

J3-6

SLOT4-M2-D3

MOD2-DATIO3

J3-7

SLOT4-M2-D4

MOD2-DATIO4

J3-12

SLOT4-M2-D5

MOD2-DATIO5

J3-20

SLOT4-M2-D6

MOD2-DATIO6

J3-14

SLOT4-M2-D7

MOD2-DATIO7

J3-24

SLOT4-M2-D8

MOD2-DATIO8

J3-21

SLOT4-M2-D9

MOD2-DATIO9

J3-32

SLOT4-M2-D10

MOD2-DATIO10

J3-22

SLOT4-M2-D11

MOD2-DATIO11

J3-33

SLOT4-M2-D12

MOD2-DATIO12

J3-23

SLOT4-M2-D13

MOD2-DATIO13

J3-34

SLOT4-M2-D14

MOD2-DATIO14

J3-35

SLOT4-M2-D15

MOD2-DATIO15

J3-47

SLOT4-M2-D16

MOD2-DATIO16

J3-30

SLOT4-M2-D17

MOD2-DATIO17

J3-42

SLOT4-M2-D18

MOD2-DATIO18

J3-31

SLOT4-M2-D19

MOD2-DATIO19

J3-43

SLOT4-M2-D20

MOD2-DATIO20

J3-44

SLOT4-M2-D21

MOD2-DATIO21

J3-56

SLOT4-M2-D22

MOD2-DATIO22

J3-45

SLOT4-M2-D23

MOD2-DATIO23

J3-57

SLOT4-M2-D24

MOD2-DATIO24

J3-46

SLOT4-M2-D25

MOD2-DATIO25

J3-58

SLOT4-M2-D26

MOD2-DATIO26

J3-53

SLOT4-M2-D27

MOD2-DATIO27

J3-65

SLOT4-M2-D28

MOD2-DATIO28

J3-54

SLOT4-M2-D29

MOD2-DATIO29

J3-66

SLOT4-M2-D30

MOD2-DATIO30

J3-55

SLOT4-M2-D31

MOD2-DATIO31

J3-67

SLOT4-M2-D32

MOD2-DATIO32

J4-68

SLOT4-M3-D1

MOD3-DATIO1

J4-69

SLOT4-M3-D2

MOD3-DATIO2

J4-70

SLOT4-M3-D3

MOD3-DATIO3

J4-81

SLOT4-M3-D4

MOD3-DATIO4

J4-77

SLOT4-M3-D5

MOD3-DATIO5

J4-88

SLOT4-M3-D6

MOD3-DATIO6

J4-78

SLOT4-M3-D7

MOD3-DATIO7

J4-89

SLOT4-M3-D8

MOD3-DATIO8

J4-79

SLOT4-M3-D9

MOD3-DATIO9

J4-90

SLOT4-M3-D10

MOD3-DATIO10

J4-80

SLOT4-M3-D11

MOD3-DATIO11

J4-91

SLOT4-M3-D12

MOD3-DATIO12

J4-92

SLOT4-M3-D13

MOD3-DATIO13

J4-103

SLOT4-M3-D14

MOD3-DATIO14

J4-93

SLOT4-M3-D15

MOD3-DATIO15

J4-104

SLOT4-M3-D16

MOD3-DATIO16

J4-100

SLOT4-M3-D17

MOD3-DATIO17

J4-111

SLOT4-M3-D18

MOD3-DATIO18

J4-101

SLOT4-M3-D19

MOD3-DATIO19

J4-112

SLOT4-M3-D20

MOD3-DATIO20

J4-102

SLOT4-M3-D21

MOD3-DATIO21

J4-113

SLOT4-M3-D22

MOD3-DATIO22

J4-110

SLOT4-M3-D23

MOD3-DATIO23

J4-119

SLOT4-M3-D24

MOD3-DATIO24

J4-114

SLOT4-M3-D25

MOD3-DATIO25

J4-121

SLOT4-M3-D26

MOD3-DATIO26

J4-118

SLOT4-M3-D27

MOD3-DATIO27

J4-125

SLOT4-M3-D28

MOD3-DATIO28

J4-120

SLOT4-M3-D29

MOD3-DATIO29

J4-126

SLOT4-M3-D30

MOD3-DATIO30

J4-127

SLOT4-M3-D31

MOD3-DATIO31

J4-128

SLOT4-M3-D32

MOD3-DATIO32

Pin-Out / General / I/O Connector (Slot 5)

J1

J2

J3

J4

SIU35 Generic I/O

75G5-Z00Z00Z000WX0X

Slave board

J4-48

SLOT5-M1-D1

MOD1-DATIO1

J4-59

SLOT5-M1-D2

MOD1-DATIO2

J4-49

SLOT5-M1-D3

MOD1-DATIO3

J4-60

SLOT5-M1-D4

MOD1-DATIO4

J4-71

SLOT5-M1-D5

MOD1-DATIO5

J4-82

SLOT5-M1-D6

MOD1-DATIO6

J4-72

SLOT5-M1-D7

MOD1-DATIO7

J4-83

SLOT5-M1-D8

MOD1-DATIO8

J4-84

SLOT5-M1-D9

MOD1-DATIO9

J4-95

SLOT5-M1-D10

MOD1-DATIO10

J4-74

SLOT5-M1-D11

MOD1-DATIO11

J4-85

SLOT5-M1-D12

MOD1-DATIO12

J4-75

SLOT5-M1-D13

MOD1-DATIO13

J4-86

SLOT5-M1-D14

MOD1-DATIO14

J4-76

SLOT5-M1-D15

MOD1-DATIO15

J4-87

SLOT5-M1-D16

MOD1-DATIO16

J4-94

SLOT5-M1-D17

MOD1-DATIO17

J4-105

SLOT5-M1-D18

MOD1-DATIO18

J4-96

SLOT5-M1-D19

MOD1-DATIO19

J4-106

SLOT5-M1-D20

MOD1-DATIO20

J4-97

SLOT5-M1-D21

MOD1-DATIO21

J4-107

SLOT5-M1-D22

MOD1-DATIO22

J4-98

SLOT5-M1-D23

MOD1-DATIO23

J4-108

SLOT5-M1-D24

MOD1-DATIO24

J4-99

SLOT5-M1-D25

MOD1-DATIO25

J4-109

SLOT5-M1-D26

MOD1-DATIO26

J4-115

SLOT5-M1-D27

MOD1-DATIO27

J4-122

SLOT5-M1-D28

MOD1-DATIO28

J4-116

SLOT5-M1-D29

MOD1-DATIO29

J4-123

SLOT5-M1-D30

MOD1-DATIO30

J4-117

SLOT5-M1-D31

MOD1-DATIO31

J4-124

SLOT5-M1-D32

MOD1-DATIO32

J4-1

SLOT5-M2-D1

MOD2-DATIO1

J4-2

SLOT5-M2-D2

MOD2-DATIO2

J4-3

SLOT5-M2-D3

MOD2-DATIO3

J4-4

SLOT5-M2-D4

MOD2-DATIO4

J4-8

SLOT5-M2-D5

MOD2-DATIO5

J4-16

SLOT5-M2-D6

MOD2-DATIO6

J4-9

SLOT5-M2-D7

MOD2-DATIO7

J4-17

SLOT5-M2-D8

MOD2-DATIO8

J4-10

SLOT5-M2-D9

MOD2-DATIO9

J4-18

SLOT5-M2-D10

MOD2-DATIO10

J4-11

SLOT5-M2-D11

MOD2-DATIO11

J4-19

SLOT5-M2-D12

MOD2-DATIO12

J4-15

SLOT5-M2-D13

MOD2-DATIO13

J4-25

SLOT5-M2-D14

MOD2-DATIO14

J4-26

SLOT5-M2-D15

MOD2-DATIO15

J4-38

SLOT5-M2-D16

MOD2-DATIO16

J4-27

SLOT5-M2-D17

MOD2-DATIO17

J4-39

SLOT5-M2-D18

MOD2-DATIO18

J4-28

SLOT5-M2-D19

MOD2-DATIO19

J4-40

SLOT5-M2-D20

MOD2-DATIO20

J4-29

SLOT5-M2-D21

MOD2-DATIO21

J4-41

SLOT5-M2-D22

MOD2-DATIO22

J4-36

SLOT5-M2-D23

MOD2-DATIO23

J4-37

SLOT5-M2-D24

MOD2-DATIO24

J4-50

SLOT5-M2-D25

MOD2-DATIO25

J4-62

SLOT5-M2-D26

MOD2-DATIO26

J4-51

SLOT5-M2-D27

MOD2-DATIO27

J4-63

SLOT5-M2-D28

MOD2-DATIO28

J4-52

SLOT5-M2-D29

MOD2-DATIO29

J4-64

SLOT5-M2-D30

MOD2-DATIO30

J4-61

SLOT5-M2-D31

MOD2-DATIO31

J4-73

SLOT5-M2-D32

MOD2-DATIO32

J4-5

SLOT5-M3-D1

MOD3-DATIO1

J4-13

SLOT5-M3-D2

MOD3-DATIO2

J4-6

SLOT5-M3-D3

MOD3-DATIO3

J4-7

SLOT5-M3-D4

MOD3-DATIO4

J4-12

SLOT5-M3-D5

MOD3-DATIO5

J4-20

SLOT5-M3-D6

MOD3-DATIO6

J4-14

SLOT5-M3-D7

MOD3-DATIO7

J4-24

SLOT5-M3-D8

MOD3-DATIO8

J4-21

SLOT5-M3-D9

MOD3-DATIO9

J4-32

SLOT5-M3-D10

MOD3-DATIO10

J4-22

SLOT5-M3-D11

MOD3-DATIO11

J4-33

SLOT5-M3-D12

MOD3-DATIO12

J4-23

SLOT5-M3-D13

MOD3-DATIO13

J4-34

SLOT5-M3-D14

MOD3-DATIO14

J4-35

SLOT5-M3-D15

MOD3-DATIO15

J4-47

SLOT5-M3-D16

MOD3-DATIO16

J4-30

SLOT5-M3-D17

MOD3-DATIO17

J4-42

SLOT5-M3-D18

MOD3-DATIO18

J4-31

SLOT5-M3-D19

MOD3-DATIO19

J4-43

SLOT5-M3-D20

MOD3-DATIO20

J4-44

SLOT5-M3-D21

MOD3-DATIO21

J4-56

SLOT5-M3-D22

MOD3-DATIO22

J4-45

SLOT5-M3-D23

MOD3-DATIO23

J4-57

SLOT5-M3-D24

MOD3-DATIO24

J4-46

SLOT5-M3-D25

MOD3-DATIO25

J4-58

SLOT5-M3-D26

MOD3-DATIO26

J4-53

SLOT5-M3-D27

MOD3-DATIO27

J4-65

SLOT5-M3-D28

MOD3-DATIO28

J4-54

SLOT5-M3-D29

MOD3-DATIO29

J4-66

SLOT5-M3-D30

MOD3-DATIO30

J4-55

SLOT5-M3-D31

MOD3-DATIO31

J4-67

SLOT5-M3-D32

MOD3-DATIO32

Pin-Out / General System Functions

J1-36

PS-ON/OFF#

J1-58

cPCI-SYSRST#

PS-ON/OFF#

Logic level open or “High” (+5V) (referenced to Input Power Return of the SIU35) enables power output of the internal PSU effectively applying power to the SLOT-1 and SLOT-5 I/O cards.

Logic level low (GND) (referenced to Input Power Return of the SIU35), disables power output of the internal PSU effectively removing power from (shutting off) SLOT-1 and SLOT-5 I/O cards.

SYSRST#

Logic level GND (referenced to internal system GND of the SIU35) initiates/applies active low assertion to the cPCI SYSRST# signal on the cards; once released, will effectively introduce a 'system/card' reset.

Note
SYSRST# function is dependent on slot 1 card type/configuration; if slot 1 card is a “controller” type card (e.g. 75PPC1 or 75G5 w/ ARM capability, then SYSRST# is routed to the “push-button” reset input of the card, and the card issues the RSTn signal on the backplane to all other “slave” cards within the chassis when SYSRST# is asserted. If the slot 1 card is a “master” type card only (e.g. 75G5-master, etc.), then the SYSRST# signal is hardwired to all cards within the chassis (all cards will have RSTn applied simultaneously).

PART NUMBER DESIGNATION

Current Part Number Designation

Current P/N designation, DOM 2019 and later.

Standard Product = SIU35-XXXX

XXXX = NAI/Factory assigned unique configuration identifier

Legacy Part Number Designation

Note
For reference only - legacy, pre-current P/N designation, DOM earlier 2019.

Standard Product = SIU35-VC-XXXX

SIU35-

V

C

-XXXX

Chassis Family

A = Standard 3U cPCI 5-slot card version (plus dedicated PSU slot) Contact factory for other than standard version

Configuration

A = Standard Configuration

B Generation-V (GEN5) optimized backplane configuration

Pre-Configured Card, Function, Slot Designation and PSU Definitions* Unique product specific configuration code assignment / identifier - contact factory.

Specifications are subject to change without notice.

Notes

*Factory assigned X-digit code will reference the complete SIU configuration information in the NAI Master Code List (MCL) or Part Number Configurator, as assigned and documented at the factory.

SIU mating connector kit part number:

cPCI Systems; 4x 128-pin & 1x 13-pin (or 1x 5-pin for AC/270 DC power input):

28 VDC Power: SIU35-CONN-KIT; 115/230 VAC / 270 VDC Power - SIU35-AC-CONN-KIT

**If your configuration option is not listed please contact factory at 1-631-567-1100

Help Bot