SYNCHRO/RESOLVER AND LVDT/RVDT SIMULATION MODULE CODE TABLES

Select the Digital-to-Synchro (DSx), Digital-to-Resolver (DRx) or Digital-to-LVDT/RVDT (DLx) module ID corresponding to the application operating parameters required from the following code table (where x = the specific module ID designator). Customer should indicate the actual frequency applicable the design to assure that the correct default band width is set at the factory. All Input and Reference voltages are auto ranging. Frequency/voltage band tolerances +/- 10%. For availability and ranges other than those listed contact the factory. Specifications may be subject to change.

  • Single Channel module pending availability (contact factory)
Module IDFormatChannel(s)Output Voltage VL-L (Vrms)Reference Voltage (Vrms)Frequency Range (Hz)Power / CH maximum (VA)Notes
DS1SYN1*2 - 282 - 11547 - 1 K3
DR1RSL
DL1LVDT/RVDT
DS2SYN1*2 - 282 - 1151 K - 5 K3
DR2RSL
DL2LVDT/RVDT
DS3SYN1*2 - 282 - 1155 K - 10 K3
DR3RSL
DL3LVDT/RVDT
DS4SYN1*2 - 282 - 11510 K - 20 K3
DR4RSL
DL4LVDT/RVDT
DS5SYN1*28 - 902 - 11547 - 1 K3
DR5RSL
DL5LVDT/RVDT
DSXSYN1*XXXXX = TBD; special configuration, requires special part number code designation, contact factory
DRXRSL
DLXLVDT/RVDT
DSASYN22 - 282 - 11547 - 1 K1.5
DRARSL
DLALVDT/RVDT
DSBSYN22 - 282 - 1151 K - 5 K1.5
DRBRSL
DLBLVDT/RVDT
DSCSYN22 - 282 - 1155 K - 10 K1.5
DRCRSL
DLCLVDT/RVDT
DSDSYN22 - 282 - 11510 K - 20 K1.5
DRDRSL
DLDLVDT/RVDT
DSESYN228 - 902 - 11547 - 1 K2.2
DRERSL
DLELVDT/RVDT
DSYSYN2YYYYY = TBD; special configuration, requires special part number code designation, contact factory
DRYRSL
DLYLVDT/RVDT
DSJSYN32 - 282 - 11547 - 1 K0.5
DRJRSL
DLJLVDT/RVDT
DSKSYN32 - 282 - 1151 K - 5 K0.5
DRKRSL
DLKLVDT/RVDT
DSLSYN32 - 282 - 1155 K - 10 K0.5
DRLRSL
DLLLVDT/RVDT
DSMSYN32 - 282 - 11510 K - 20 K0.5
DRMRSL
DLMLVDT/RVDT
DSNSYN328 - 902 - 11547 - 1 K0.5
DRNRSL
DLNLVDT/RVDT
DSZSYN3ZZZZZ = TBD; special configuration, requires special part number code designation, contact factory
DRZRSL
DLZLVDT/RVDT

SYNCHRO/RESOLVER AND LVDT/RVDT MEASUREMENT MODULE CODE TABLES

SYN/RSL Four-Channel Measurement (Field Programmable SYN/RSL)

Select the Synchro/Resolver-to-Digital (SDx) module ID corresponding to the application operating parameters required from the following code table (where x = the specific module ID designator). Customer should indicate the actual frequency applicable to the design to assure that the correct default band width is set at the factory. All Input and Reference voltages are auto ranging. For availability and ranges other than those listed contact the factory. Specifications may be subject to change.

Frequency/voltage band tolerances +/- 10%.

Module IDInput Voltage V (Vrms)Reference Voltage + (Vrms)Frequency Range + (Hz)Notes
SD12 - 282 - 11547 - 1 K
SD22 - 282 - 1151K - 5 K
SD32 - 282 - 1155K - 10 K
SD4*2 - 282 - 11510K - 20 K
SD528 - 902 - 11547 - 1 K
SDX*XXXX = TBD; special configuration, requires special part number code designation, contact factory

*Consult factory for availability

LVDT/RVDT Four-Channel Measurement (Field Programmable 2, 3 or 4-Wire)

Select the LVDT/RVDT-to-Digital (LDx) module ID corresponding to the application operating parameters required from the following code table (where x = the specific module ID designator). Customer should indicate the actual frequency applicable to the design to assure that the correct default band width is set at the factory. All Input and Excitation voltages are auto ranging. For availability and ranges other than those listed contact the factory. Specifications may be subject to change.

Frequency/voltage band tolerances +/- 10%.

Module IDInput Signal Voltage V + (Vrms)Excitation Voltage + (Vrms)Frequency Range + (Hz)Notes
LD12 - 282 - 11547 - 1 K
LD22 - 282 - 1151K - 5 K
LD32 - 282 - 1155K - 10 K
LD4*2 - 282 - 11510K - 20 K
LD528 - 902 - 11547 - 1 K
LDX*XXXX = TBD; special configuration, requires special part number code designation, contact factory

*Consult factory for availability