Module Control Command Registers

Modules Control Command Requests
Function:Provides the ability to command individual Modules to Reset, Power-down, or Power-up.
Type:unsigned binary word (32-bit)
Data Range:0x0000 0000 to 0xFFFF FFFF
Read/Write:R/W
Operational Settings:The Module Control Commands registers provide the ability to request individual Modules to perform one of the following functions - Reset, Power-down, Power-up. Only one command can be requested at a time per Module. For example, one can't request a Reset and a Power-down at the same time for the same Module. Once the command is recognized and handled, the bit will be cleared.

Note

Clearing of the command request bit only indicates the command has been recognized and initiated, it does not indicate that the command action has been completed.

There is one Control Command Request register per Module. Each register is Bit-mapped as shown in the table below:

Bit(s)Description
D31:D3Reserved
D2Module Power-up
D1Module Power-down
D0Module Reset