Zynq Core Voltage

Function: Specifies the Measured Zynq Core Voltage.

Type: unsigned word (16-bits) for integer part and unsigned word (16-bits) for fractional part

Data Range: 0x0000 0000 to 0xFFFF FFFF

Read/Write: R

Initialized Value: Value corresponding to the Measured Zynq Core Voltage (based on the conversion below)

Operational Settings: The upper 16-bits are the Integer part of the Voltage and the lower 16-bits is the Fractional part of the Voltage. For example, if the register contains the value 0x0000 03DE, this represents 0.990 Volts.

Zynq Core Voltage

D31D30D29D28D27D26D25D24D23D22D21D20D19D18D17D16
Integer part of Voltage
D15D14D13D12D11D10D9D8D7D6D5D4D3D2D1D0
Fractional part of Voltage